# Optimal Sensor Placement in Body Surface Networks using Gaussian Processes

arXiv: https://arxiv.org/abs/2209.02912 · HTML: https://mlsanity.com/paper/2209.02912/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 7 of its 38 references that are in the map.
- First posted on arXiv 7 Sep 2022.

## Builds on (most cited first, 7 of 7)

- [When Gaussian Process Meets Big Data: A Review of Scalable GPs](https://mlsanity.com/paper/1807.01065/) (2018)
- [Kernel Interpolation for Scalable Structured Gaussian Processes (KISS-GP)](https://mlsanity.com/paper/1503.01057/) (2015)
- [Gaussian Process Kernels for Pattern Discovery and Extrapolation](https://mlsanity.com/paper/1302.4245/) (2013)
- [Local Gaussian process approximation for large computer experiments](https://mlsanity.com/paper/1303.0383/) (2013)
- [Gaussian Process Landmarking on Manifolds](https://mlsanity.com/paper/1802.03479/) (2018)
- [Gaussian Process Regression for Arctic Coastal Erosion Forecasting](https://mlsanity.com/paper/1712.00867/) (2017)
- [Scalable Gaussian Process Regression for Kernels with a Non-Stationary Phase](https://mlsanity.com/paper/1912.11713/) (2019)

## Abstract (arXiv)

This paper explores a new sequential selection framework for the optimal sensor placement (OSP) in Electrocardiography imaging networks (ECGI). The proposed methodology incorporates the use a recent experimental design method for the sequential selection of landmarkings on biological objects, namely, Gaussian process landmarking (GPLMK) for better exploration of the candidate sensors. The two experimental design methods work as a source of the training and the validation locations which is fitted using a spatiotemporal Gaussian process (STGP). The STGP is fitted using the training set to predict for the current validation set generated using GPLMK, and the sensor with the largest prediction absolute error is selected from the current validation set and added to the selected sensors. Next, a new validation set is generated and predicted using the current training set. The process continues until selecting a specific number of sensor locations. The study is conducted on a dataset of body surface potential mapping (BSPM) of 352 electrodes of four human subjects. A number of 30 sensor locations is selected using the proposed algorithm. The selected sensor locations achieved average R2 = 94.40 % for estimating the whole-body QRS segment. The proposed method adds to design efforts for a more clinically practical ECGI system by improving its wearability and reduce the design cost as well.
