# Convolutional Neural Network to Restore Low-Dose Digital Breast Tomosynthesis Projections in a Variance Stabilization Domain

arXiv: https://arxiv.org/abs/2203.11722 · HTML: https://mlsanity.com/paper/2203.11722/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 8 of its 44 references that are in the map.
- First posted on arXiv 22 Mar 2022.

## Builds on (most cited first, 8 of 8)

- [Deep Residual Learning for Image Recognition](https://mlsanity.com/paper/1512.03385/) (2015)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [Learned Primal-dual Reconstruction](https://mlsanity.com/paper/1707.06474/) (2017)
- [Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)](https://mlsanity.com/paper/1702.00288/) (2017)
- [A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstruction](https://mlsanity.com/paper/1610.09736/) (2016)
- [Can Deep Learning Outperform Modern Commercial CT Image Reconstruction Methods?](https://mlsanity.com/paper/1811.03691/) (2018)
- [3D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning from a 2D Trained Network](https://mlsanity.com/paper/1802.05656/) (2018)
- [Impact of loss functions on the performance of a deep neural network designed to restore low-dose digital mammography](https://mlsanity.com/paper/2111.06890/) (2021)

## Abstract (arXiv)

Digital breast tomosynthesis (DBT) exams should utilize the lowest possible radiation dose while maintaining sufficiently good image quality for accurate medical diagnosis. In this work, we propose a convolution neural network (CNN) to restore low-dose (LD) DBT projections to achieve an image quality equivalent to a standard full-dose (FD) acquisition. The proposed network architecture benefits from priors in terms of layers that were inspired by traditional model-based (MB) restoration methods, considering a model-based deep learning approach, where the network is trained to operate in the variance stabilization transformation (VST) domain. To accurately control the network operation point, in terms of noise and blur of the restored image, we propose a loss function that minimizes the bias and matches residual noise between the input and the output. The training dataset was composed of clinical data acquired at the standard FD and low-dose pairs obtained by the injection of quantum noise. The network was tested using real DBT projections acquired with a physical anthropomorphic breast phantom. The proposed network achieved superior results in terms of the mean normalized squared error (MNSE), training time and noise spatial correlation compared with networks trained with traditional data-driven methods. The proposed approach can be extended for other medical imaging application that requires LD acquisitions.