# Analysing the Performance of Stress Detection Models on Consumer-Grade Wearable Devices

arXiv: https://arxiv.org/abs/2203.09669 · HTML: https://mlsanity.com/paper/2203.09669/

## Key facts

- Cited by 3 papers in the map (data through 14 Oct 2026).
- Builds on 3 of its 27 references that are in the map.
- First posted on arXiv 18 Mar 2022.

## Builds on (most cited first, 3 of 3)

- [Online Human Activity Recognition using Low-Power Wearable Devices](https://mlsanity.com/paper/1808.08615/) (2018)
- [The Effect of Person-Specific Biometrics in Improving Generic Stress Predictive Models](https://mlsanity.com/paper/1910.01770/) (2019)
- [Wearable affect and stress recognition: A review](https://mlsanity.com/paper/1811.08854/) (2018)

## Built on by (most cited first, 3 of 3)

- [Ensemble Machine Learning Model Trained on a New Synthesized Dataset Generalizes Well for Stress Prediction Using Wearable Devices](https://mlsanity.com/paper/2209.15146/) (2022)
- [Exploration of Low-Power Flexible Stress Monitoring Classifiers for Conformal Wearables](https://mlsanity.com/paper/2508.19661/) (2025)
- [Personalization of Stress Mobile Sensing using Self-Supervised Learning](https://mlsanity.com/paper/2308.02731/) (2023)

## Abstract (arXiv)

Identifying stress levels can provide valuable data for mental health analytics as well as labels for annotation systems. Although much research has been conducted into stress detection models using heart rate variability at a higher cost of data collection, there is a lack of research on the potential of using low-resolution Electrodermal Activity (EDA) signals from consumer-grade wearable devices to identify stress patterns. In this paper, we concentrate on performing statistical analyses on the stress detection capability of two popular approaches of training stress detection models with stress-related biometric signals: user-dependent and user-independent models. Our research manages to show that user-dependent models are statistically more accurate for stress detection. In terms of effectiveness assessment, the balanced accuracy (BA) metric is employed to evaluate the capability of distinguishing stress and non-stress conditions of the models trained on either low-resolution or high-resolution Electrodermal Activity (EDA) signals. The results from the experiment show that training the model with (comparatively low-cost) low-resolution EDA signal does not affect the stress detection accuracy of the model significantly compared to using a high-resolution EDA signal. Our research results demonstrate the potential of attaching the user-dependent stress detection model trained on personal low-resolution EDA signal recorded to collect data in daily life to provide users with personal stress level insight and analysis.
