# BP-Net: Efficient Deep Learning for Continuous Arterial Blood Pressure Estimation using Photoplethysmogram

arXiv: https://arxiv.org/abs/2111.14558 · HTML: https://mlsanity.com/paper/2111.14558/

## Key facts

- Cited by 5 papers in the map (data through 14 Oct 2026).
- Builds on 3 of its 35 references that are in the map.
- First posted on arXiv 29 Nov 2021.

## Builds on (most cited first, 3 of 3)

- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [U-Net and its variants for medical image segmentation: theory and applications](https://mlsanity.com/paper/2011.01118/) (2020)
- [End-to-End Deep Learning for Reliable Cardiac Activity Monitoring using Seismocardiograms](https://mlsanity.com/paper/2010.05662/) (2020)

## Built on by (most cited first, 5 of 5)

- [Region-Disentangled Diffusion Model for High-Fidelity PPG-to-ECG Translation](https://mlsanity.com/paper/2308.13568/) (2023)
- [Constraint Latent Space Matters: An Anti-anomalous Waveform Transformation Solution from Photoplethysmography to Arterial Blood Pressure](https://mlsanity.com/paper/2402.17780/) (2024)
- [MD-ViSCo: A Unified Model for Multi-Directional Vital Sign Waveform Conversion](https://mlsanity.com/paper/2506.08357/) (2025)
- [Collaborative Learning-Enhanced Lightweight Models for Predicting Arterial Blood Pressure Waveform in a Large-scale Perioperative Dataset](https://mlsanity.com/paper/2508.11669/) (2025)
- [End-to-end Automated Deep Neural Network Optimization for PPG-based Blood Pressure Estimation on Wearables](https://mlsanity.com/paper/2604.10117/) (2026)

## Abstract (arXiv)

Blood pressure (BP) is one of the most influential bio-markers for cardiovascular diseases and stroke; therefore, it needs to be regularly monitored to diagnose and prevent any advent of medical complications. Current cuffless approaches to continuous BP monitoring, though non-invasive and unobtrusive, involve explicit feature engineering surrounding fingertip Photoplethysmogram (PPG) signals. To circumvent this, we present an end-to-end deep learning solution, BP-Net, that uses PPG waveform to estimate Systolic BP (SBP), Mean Average Pressure (MAP), and Diastolic BP (DBP) through intermediate continuous Arterial BP (ABP) waveform. Under the terms of the British Hypertension Society (BHS) standard, BP-Net achieves Grade A for DBP and MAP estimation and Grade B for SBP estimation. BP-Net also satisfies Advancement of Medical Instrumentation (AAMI) criteria for DBP and MAP estimation and achieves Mean Absolute Error (MAE) of 5.16 mmHg and 2.89 mmHg for SBP and DBP, respectively. Further, we establish the ubiquitous potential of our approach by deploying BP-Net on a Raspberry Pi 4 device and achieve 4.25 ms inference time for our model to translate the PPG waveform to ABP waveform.
