# Inter-Beat Interval Estimation with Tiramisu Model: A Novel Approach with Reduced Error

arXiv: https://arxiv.org/abs/2107.00693 · HTML: https://mlsanity.com/paper/2107.00693/

## Key facts

- Cited by 1 papers in the map (data through 14 Oct 2026).
- Builds on 5 of its 66 references that are in the map.
- First posted on arXiv 1 Jul 2021.

## Builds on (most cited first, 5 of 5)

- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [The One Hundred Layers Tiramisu: Fully Convolutional DenseNets for Semantic Segmentation](https://mlsanity.com/paper/1611.09326/) (2016)
- [TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise](https://mlsanity.com/paper/1409.5181/) (2014)
- [RPnet: A Deep Learning approach for robust R Peak detection in noisy ECG](https://mlsanity.com/paper/2004.08103/) (2020)
- [A Generative Adversarial Approach To ECG Synthesis And Denoising](https://mlsanity.com/paper/2009.02700/) (2020)

## Built on by (most cited first, 1 of 1)

- [Trustworthy AI in Digital Health: A Comprehensive Review of Robustness and Explainability](https://mlsanity.com/paper/2608.02238/) (2026)

## Abstract (arXiv)

Inter-beat interval (IBI) measurement enables estimation of heart-rate variability (HRV) which, in turns, can provide early indication of potential cardiovascular diseases. However, extracting IBIs from noisy signals is challenging since the morphology of the signal is distorted in the presence of the noise. Electrocardiogram (ECG) of a person in heavy motion is highly corrupted with noise, known as motion-artifact, and IBI extracted from it is inaccurate. As a part of remote health monitoring and wearable system development, denoising ECG signals and estimating IBIs correctly from them have become an emerging topic among signal-processing researchers. Apart from conventional methods, deep-learning techniques have been successfully used in signal denoising recently, and diagnosis process has become easier, leading to accuracy levels that were previously unachievable. We propose a deep-learning approach leveraging tiramisu autoencoder model to suppress motion-artifact noise and make the R-peaks of the ECG signal prominent even in the presence of high-intensity motion. After denoising, IBIs are estimated more accurately expediting diagnosis tasks. Results illustrate that our method enables IBI estimation from noisy ECG signals with SNR up to -30dB with average root mean square error (RMSE) of 13 milliseconds for estimated IBIs. At this noise level, our error percentage remains below 8% and outperforms other state of the art techniques.
