# Continuous Monitoring of Blood Pressure with Evidential Regression

arXiv: https://arxiv.org/abs/2102.03542 · HTML: https://mlsanity.com/paper/2102.03542/

## Key facts

- No citing papers in the map yet (data through 14 Oct 2026).
- Builds on 10 of its 31 references that are in the map.
- First posted on arXiv 6 Feb 2021.

## Builds on (most cited first, 10 of 10)

- [Deep Residual Learning for Image Recognition](https://mlsanity.com/paper/1512.03385/) (2015)
- [Adam: A Method for Stochastic Optimization](https://mlsanity.com/paper/1412.6980/) (2014)
- [U-Net: Convolutional Networks for Biomedical Image Segmentation](https://mlsanity.com/paper/1505.04597/) (2015)
- [Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift](https://mlsanity.com/paper/1502.03167/) (2015)
- [On Calibration of Modern Neural Networks](https://mlsanity.com/paper/1706.04599/) (2017)
- [Learning Phrase Representations using RNN Encoder-Decoder for Statistical Machine Translation](https://mlsanity.com/paper/1406.1078/) (2014)
- [Language Modeling with Gated Convolutional Networks](https://mlsanity.com/paper/1612.08083/) (2016)
- [Weight Normalization: A Simple Reparameterization to Accelerate Training of Deep Neural Networks](https://mlsanity.com/paper/1602.07868/) (2016)
- [Deep Evidential Regression](https://mlsanity.com/paper/1910.02600/) (2019)
- [Music Source Separation in the Waveform Domain](https://mlsanity.com/paper/1911.13254/) (2019)

## Abstract (arXiv)

Photoplethysmogram (PPG) signal-based blood pressure (BP) estimation is a promising candidate for modern BP measurements, as PPG signals can be easily obtained from wearable devices in a non-invasive manner, allowing quick BP measurement. However, the performance of existing machine learning-based BP measuring methods still fall behind some BP measurement guidelines and most of them provide only point estimates of systolic blood pressure (SBP) and diastolic blood pressure (DBP). In this paper, we present a cutting-edge method which is capable of continuously monitoring BP from the PPG signal and satisfies healthcare criteria such as the Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) standards. Furthermore, the proposed method provides the reliability of the predicted BP by estimating its uncertainty to help diagnose medical condition based on the model prediction. Experiments on the MIMIC II database verify the state-of-the-art performance of the proposed method under several metrics and its ability to accurately represent uncertainty in prediction.