# Image quality assessment for closed-loop computer-assisted lung ultrasound

arXiv: https://arxiv.org/abs/2008.08840 · HTML: https://mlsanity.com/paper/2008.08840/

## Key facts

- Cited by 6 papers in the map (data through 14 Oct 2026).
- First posted on arXiv 20 Aug 2020.

## Built on by (most cited first, 6 of 6)

- [Image quality assessment for machine learning tasks using meta-reinforcement learning](https://mlsanity.com/paper/2203.14258/) (2022)
- [Image quality assessment by overlapping task-specific and task-agnostic measures: application to prostate multiparametric MR images for cancer segmentation](https://mlsanity.com/paper/2202.09798/) (2022)
- [Adaptable image quality assessment using meta-reinforcement learning of task amenability](https://mlsanity.com/paper/2108.04359/) (2021)
- [Learning image quality assessment by reinforcing task amenable data selection](https://mlsanity.com/paper/2102.07615/) (2021)
- [Lung Ultrasound Segmentation and Adaptation between COVID-19 and Community-Acquired Pneumonia](https://mlsanity.com/paper/2108.03138/) (2021)
- [Rapid Lung Ultrasound COVID-19 Severity Scoring with Resource-Efficient Deep Feature Extraction](https://mlsanity.com/paper/2207.10998/) (2022)

## Abstract (arXiv)

We describe a novel, two-stage computer assistance system for lung anomaly detection using ultrasound imaging in the intensive care setting to improve operator performance and patient stratification during coronavirus pandemics. The proposed system consists of two deep-learning-based models: a quality assessment module that automates predictions of image quality, and a diagnosis assistance module that determines the likelihood-oh-anomaly in ultrasound images of sufficient quality. Our two-stage strategy uses a novelty detection algorithm to address the lack of control cases available for training the quality assessment classifier. The diagnosis assistance module can then be trained with data that are deemed of sufficient quality, guaranteed by the closed-loop feedback mechanism from the quality assessment module. Using more than 25000 ultrasound images from 37 COVID-19-positive patients scanned at two hospitals, plus 12 control cases, this study demonstrates the feasibility of using the proposed machine learning approach. We report an accuracy of 86% when classifying between sufficient and insufficient quality images by the quality assessment module. For data of sufficient quality - as determined by the quality assessment module - the mean classification accuracy, sensitivity, and specificity in detecting COVID-19-positive cases were 0.95, 0.91, and 0.97, respectively, across five holdout test data sets unseen during the training of any networks within the proposed system. Overall, the integration of the two modules yields accurate, fast, and practical acquisition guidance and diagnostic assistance for patients with suspected respiratory conditions at point-of-care.
