# A Learning-based Method for Online Adjustment of C-arm Cone-Beam CT Source Trajectories for Artifact Avoidance

arXiv: https://arxiv.org/abs/2008.06262 · HTML: https://mlsanity.com/paper/2008.06262/

## Key facts

- Cited by 6 papers in the map (data through 14 Oct 2026).
- First posted on arXiv 14 Aug 2020.

## Built on by (most cited first, 6 of 6)

- [The Impact of Machine Learning on 2D/3D Registration for Image-guided Interventions: A Systematic Review and Perspective](https://mlsanity.com/paper/2108.02238/) (2021)
- [Known Operator Learning and Hybrid Machine Learning in Medical Imaging -- A Review of the Past, the Present, and the Future](https://mlsanity.com/paper/2108.04543/) (2021)
- [SyntheX: Scaling Up Learning-based X-ray Image Analysis Through In Silico Experiments](https://mlsanity.com/paper/2206.06127/) (2022)
- [Artifact Reduction in 3D and 4D Cone-beam Computed Tomography Images with Deep Learning -- A Review](https://mlsanity.com/paper/2403.18565/) (2024)
- [Task-based Generation of Optimized Projection Sets using Differentiable Ranking](https://mlsanity.com/paper/2303.11724/) (2023)
- [Enhanced artificial intelligence-based diagnosis using CBCT with internal denoising: Clinical validation for discrimination of fungal ball, sinusitis, and normal cases in the maxillary sinus](https://mlsanity.com/paper/2211.15950/) (2022)

## Abstract (arXiv)

During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides intraoperative 3D tomographic imaging which would allow for immediate verification and, if needed, revision. However, the reconstruction quality attainable with commercial CBCT devices is insufficient, predominantly due to severe metal artifacts in the presence of pedicle screws. These artifacts arise from a mismatch between the true physics of image formation and an idealized model thereof assumed during reconstruction. Prospectively acquiring views onto anatomy that are least affected by this mismatch can, therefore, improve reconstruction quality. We propose to adjust the C-arm CBCT source trajectory during the scan to optimize reconstruction quality with respect to a certain task, i.e. verification of screw placement. Adjustments are performed on-the-fly using a convolutional neural network that regresses a quality index for possible next views given the current x-ray image. Adjusting the CBCT trajectory to acquire the recommended views results in non-circular source orbits that avoid poor images, and thus, data inconsistencies. We demonstrate that convolutional neural networks trained on realistically simulated data are capable of predicting quality metrics that enable scene-specific adjustments of the CBCT source trajectory. Using both realistically simulated data and real CBCT acquisitions of a semi-anthropomorphic phantom, we show that tomographic reconstructions of the resulting scene-specific CBCT acquisitions exhibit improved image quality particularly in terms of metal artifacts. Since the optimization objective is implicitly encoded in a neural network, the proposed approach overcomes the need for 3D information at run-time.
