# Deep learning-based Real-time Volumetric Imaging for Lung Stereotactic Body Radiation Therapy: A Proof of Concept Study

arXiv: https://arxiv.org/abs/2005.11832 · HTML: https://mlsanity.com/paper/2005.11832/

## Key facts

- Cited by 2 papers in the map (data through 14 Oct 2026).
- First posted on arXiv 24 May 2020.

## Built on by (most cited first, 2 of 2)

- [Accurate Patient Alignment without Unnecessary Imaging Dose via Synthesizing Patient-specific 3D CT Images from 2D kV Images](https://mlsanity.com/paper/2405.19338/) (2024)
- [RT-SRTS: Angle-Agnostic Real-Time Simultaneous 3D Reconstruction and Tumor Segmentation from Single X-Ray Projection](https://mlsanity.com/paper/2310.08080/) (2023)

## Abstract (arXiv)

Due to the inter- and intra- variation of respiratory motion, it is highly desired to provide real-time volumetric images during the treatment delivery of lung stereotactic body radiation therapy (SBRT) for accurate and active motion management. In this proof-of-concept study, we propose a novel generative adversarial network integrated with perceptual supervision to derive instantaneous volumetric images from a single 2D projection. Our proposed network, named TransNet, consists of three modules, i.e., encoding, transformation and decoding modules. Rather than only using image distance loss between the generated 3D images and the ground truth 3D CT images to supervise the network, perceptual loss in feature space is integrated into loss function to force the TransNet to yield accurate lung boundary. Adversarial supervision is also used to improve the realism of generated 3D images. We conducted a simulation study on 20 patient cases, who had received lung SBRT treatments in our institution and undergone 4D-CT simulation, and evaluated the efficacy and consistency of our method for four different projection angles, i.e., 0, 30, 60 and 90 degree. For each 3D CT image set of a breathing phase, we simulated its 2D projections at these angles.Then for each projection angle, a patient's 3D CT images of 9 phases and the corresponding 2D projection data were used for training, with the remaining phase used for testing. The mean absolute error, normalized MAE, peak signal-to-noise ratio and structural similarity index metric achieved by our method are 99.3 HU, 0.032, 23.4 dB and 0.949, respectively. These results demonstrate the feasibility and efficacy of our 2D-to-3D method for lung cancer patients, which provides a potential solution for in-treatment real-time on-board volumetric imaging for accurate dose delivery to ensure the effectiveness of lung SBRT treatment.
