# Applying Depth-Sensing to Automated Surgical Manipulation with a da Vinci Robot

arXiv: https://arxiv.org/abs/2002.06302 · HTML: https://mlsanity.com/paper/2002.06302/

## Key facts

- Cited by 8 papers in the map (data through 14 Oct 2026).
- First posted on arXiv 15 Feb 2020.

## Built on by (most cited first, 8 of 8)

- [SurRoL: An Open-source Reinforcement Learning Centered and dVRK Compatible Platform for Surgical Robot Learning](https://mlsanity.com/paper/2108.13035/) (2021)
- [Wild ToFu: Improving Range and Quality of Indirect Time-of-Flight Depth with RGB Fusion in Challenging Environments](https://mlsanity.com/paper/2112.03750/) (2021)
- [From Monocular Vision to Autonomous Action: Guiding Tumor Resection via 3D Reconstruction](https://mlsanity.com/paper/2503.16263/) (2025)
- [ActiveZero: Mixed Domain Learning for Active Stereovision with Zero Annotation](https://mlsanity.com/paper/2112.02772/) (2021)
- [Robust Surgical Tool Tracking with Pixel-based Probabilities for Projected Geometric Primitives](https://mlsanity.com/paper/2403.04971/) (2024)
- [Depth Monocular Estimation with Attention-based Encoder-Decoder Network from Single Image](https://mlsanity.com/paper/2210.13646/) (2022)
- [Real-time Rendering-based Surgical Instrument Tracking via Evolutionary Optimization](https://mlsanity.com/paper/2603.11404/) (2026)
- [Robust Surgical Robotic Instrument Tracking via Sequential Multi-Cue Fusion and Sim-to-Real Self-Training](https://mlsanity.com/paper/2610.05491/) (2026)

## Abstract (arXiv)

Recent advances in depth-sensing have significantly increased accuracy, resolution, and frame rate, as shown in the 1920x1200 resolution and 13 frames per second Zivid RGBD camera. In this study, we explore the potential of depth sensing for efficient and reliable automation of surgical subtasks. We consider a monochrome (all red) version of the peg transfer task from the Fundamentals of Laparoscopic Surgery training suite implemented with the da Vinci Research Kit (dVRK). We use calibration techniques that allow the imprecise, cable-driven da Vinci to reduce error from 4-5 mm to 1-2 mm in the task space. We report experimental results for a handover-free version of the peg transfer task, performing 20 and 5 physical episodes with single- and bilateral-arm setups, respectively. Results over 236 and 49 total block transfer attempts for the single- and bilateral-arm peg transfer cases suggest that reliability can be attained with 86.9 % and 78.0 % for each individual block, with respective block transfer speeds of 10.02 and 5.72 seconds. Supplementary material is available at https://sites.google.com/view/peg-transfer.
