# Automated quantification of myocardial tissue characteristics from native T1 mapping using neural networks with Bayesian inference for uncertainty-based quality-control

arXiv: https://arxiv.org/abs/2001.11711 · HTML: https://mlsanity.com/paper/2001.11711/

## Key facts

- Cited by 6 papers in the map (data through 14 Oct 2026).
- First posted on arXiv 31 Jan 2020.

## Built on by (most cited first, 6 of 6)

- [Trustworthy clinical AI solutions: a unified review of uncertainty quantification in deep learning models for medical image analysis](https://mlsanity.com/paper/2210.03736/) (2022)
- [Conformal Performance Range Prediction for Segmentation Output Quality Control](https://mlsanity.com/paper/2407.13307/) (2024)
- [Efficient Model Monitoring for Quality Control in Cardiac Image Segmentation](https://mlsanity.com/paper/2104.05533/) (2021)
- [FUSQA: Fetal Ultrasound Segmentation Quality Assessment](https://mlsanity.com/paper/2303.04418/) (2023)
- [An AI tool for automated analysis of large-scale unstructured clinical cine CMR databases](https://mlsanity.com/paper/2206.08137/) (2022)
- [Temporal Uncertainty Localization to Enable Human-in-the-loop Analysis of Dynamic Contrast-enhanced Cardiac MRI Datasets](https://mlsanity.com/paper/2308.13488/) (2023)

## Abstract (arXiv)

Tissue characterisation with CMR parametric mapping has the potential to detect and quantify both focal and diffuse alterations in myocardial structure not assessable by late gadolinium enhancement. Native T1 mapping in particular has shown promise as a useful biomarker to support diagnostic, therapeutic and prognostic decision-making in ischaemic and non-ischaemic cardiomyopathies. Convolutional neural networks with Bayesian inference are a category of artificial neural networks which model the uncertainty of the network output. This study presents an automated framework for tissue characterisation from native ShMOLLI T1 mapping at 1.5T using a Probabilistic Hierarchical Segmentation (PHiSeg) network. In addition, we use the uncertainty information provided by the PHiSeg network in a novel automated quality control (QC) step to identify uncertain T1 values. The PHiSeg network and QC were validated against manual analysis on a cohort of the UK Biobank containing healthy subjects and chronic cardiomyopathy patients. We used the proposed method to obtain reference T1 ranges for the left ventricular myocardium in healthy subjects as well as common clinical cardiac conditions. T1 values computed from automatic and manual segmentations were highly correlated (r=0.97). Bland-Altman analysis showed good agreement between the automated and manual measurements. The average Dice metric was 0.84 for the left ventricular myocardium. The sensitivity of detection of erroneous outputs was 91%. Finally, T1 values were automatically derived from 14,683 CMR exams from the UK Biobank. The proposed pipeline allows for automatic analysis of myocardial native T1 mapping and includes a QC process to detect potentially erroneous results. T1 reference values were presented for healthy subjects and common clinical cardiac conditions from the largest cohort to date using T1-mapping images.
